29 – Fall protection systems and falling object protection-criteria and practices. - Size: (L x W x H) 23” X 23” X 44”. 501 (b) (1) through (b) (14), each employee on a walking/working surface 6 feet (1. In sum, the plain language of §1926. 502(b), including the top rail height requirement in §1926. 6 m) above a lower level shall be protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems. ing by the use of guardrail systems, safety net systems, or personal fall ar-rest systems. The requirements for a guardrail system are stated in §1926. LAYOUT & INSTALLATION Railing height to be 42in when installed correctly. OSHA 1910 Occupational Safety and Health Standards > D Walking-Working Surfaces > 1910. Steel guardrail system manufacturers test their systems to withstand impacts from a 10,000-pound (4,500 kg) load moving at four miles per hour (6. Single midrails, where permitted, shall be not less than 2-inch by 4-inch nominal material and installed on the contact side of the guardrail. 79 - $253. All fall protection required by this section shall conform to the criteria set forth in 1926. 6 series), a worker need only be protected from falling by a properly designed and maintained guardrail system. When Does OSHA Require Guardrail? The following is an excerpt from OSHA 1910. Option for our straight, curved, or designer. 29(b)(3) Guardrail systems are capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied in a downward or outward direction within 2. The ballasted guardrail is a fast, easy, and economical way to erect temporary and permanent guardrail systems to keep workers safe. 3. Product: Permanent Guardrail System. Use a non-penetrating guardrail that doesn’t mount to any structure on your building. Talk to an Expert. However, the intermediate rail does not have a bending strength equivalent to that. (a) General. (8) Repair pits, service pits, and assembly pits less than 10 feet in depth. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. 814-623-8125 . Spatz The Graham Company One Penn Square West Philadelphia, PA 19102. 1926. 502(b), including the top rail height requirement in §1926. A single avoidable workplace incident is a potentially traumatic event for all personnel involved, meaning. Guardrails should be inspected per the manufacturer specifications or a qualified person’s requirements. Discuss the learning objectives for Section 4. 23 & 1926. 29 (f) (1) (i) - Handrails are not less than 30 inches (76 cm) and not more than 38 inches (97 cm. TOP 5 SECTIONS CITED: 1926. This section stipulates, in full detail, how guardrails and other safety barriers should be designed, installed, inspected, tested, and maintained in a manner that will prevent employees from falling. EDGE Fall Protection’s Cal OSHA Guardrail is a system specifically designed for compliance with California OSHA Title 9, 1620 and 3209 regulations. Definitions. The 360 Hide-A-Rail Collapsible Guardrail System is a completely non-penetrating Safety Rail system that has been independently certified and tested to meet all OSHA Fall Protection regulations and standards for guardrail, sections 1910. Safety Railing. These regulations were issued by the U. 6 m) from the roof edge, the employer must ensure each employee is protected from falling. OSHA's guardrail height requirements include a variance of plus or minus 3 inches. GuardRail 200 Permanent mount family of products can be used for a wide variety of fall prevention applications and so much more. O. Combine rails, posts, and gates to make a custom guardrail system. 502(b)(3) requires that a guardrail structure be able to withstand a 200-lb force (such as a worker weighing 200 lbs or more falling into the guardrail). use of guardrail systems, personal fall arrest systems, or safety net systems and access to the zone is controlled. This can be deployed around shipping pits, mezzanine perimeters, or a1926. Standard Number: 1926. 501(b)(6), Ramps, Runways, and Other Walkways, which specifies guardrail systems only. The GuardRail protective railing system comes in two styles: Single or Double Rail. Trusted Around The World. Jeffrey A. Conventional Fall Protection Systems: Guardrail Systems: Barriers called guardrail systems are built to prevent fall injuries. 593. 500-1926. Single-point or two-point adjustable suspension scaffolds require both a PFAS and a guardrail system for protection. Plan and organize the work at height through work permit system and the Job Safety Analysis. Double guard rail columns are 43″ high. The Nystrom OSHA compliant Weighted Base Guardrail is a portable railing system that is designed to keep people safe while working on the rooftops and other structures. Or, give us a call: 1-800-353-9425. e. A Railing System - Easy to Order and Build . Where a mason performs overhand bricklaying and related work 6 feet above lower levels, the requirements for fall protection systems can be satisfied by the use of guardrail systems, safety net systems, personal fall arrest systems, or by creating a controlled access zone in which the mason works. Automotive. 21 (b) Definitions . * * * * * * (b)(1) * * * (2) Leading edges. Other evidence in the record, however, indicates that there are many portable and stand-alone fall protection systems available and in use today in both the rail and truck transportation industries, including overhead cable line systems, moveable stairs with railings, mobile access platforms with railings and/or safety cages and overhead. 1926. 502 sets forth technical requirements for the protective devices set forth in section 1926. Background: The type of fall protection required by the standard depends to some extent on the work activity. 13 . 501(b)(13), which requires fall protection (usually conventional fall protection, i. The top rail must be at least 42 inches in height (§1910. system, except those on single-point and two-point adjustable suspension scaffolds. The top edge height may exceed 45 inches (114 cm), provided the guardrail system meets all other criteria of paragraph (b) of this section (see Figure D-11 of this section). Time is money… so we designed the Hilmerson Safety Rail System™ for rapid and simple installation. 502(g)(l)(iv) requires that the control line be connected on each side to a guardrail system or wall. Guardrails are to be between 38 inches and 45 inches in height, and installation of midrails at about half that height. IMPORTANCE OF SAFETY RAILING SYSTEMS - APR 2023; ERECTASTEP CROSSOVER STAIRS - MAR 2023; INFORMATION ON FIXED LADDER LIFELINES - DEC 2022;(c) Safety net systems. You stated that the freestanding guardrail system meets the 200 pound (890 N) force requirements required by 29 CFR 1926. 0 ˜ . , writes in EHS Today that the old rule emphasized the use of. In accordance with 29 CFR § 1910. A guardrail consists of a top rail 42” + or – 3” no less than 39”, mid rail at 21” and toe board. 5 inches (9 cm) as measured from the top edge of the toeboard to the level of the. Guardrail Basics: What You Need to Know | EHS Today America's Safest Companies OSHA’s fall protection and guardrail requirements along with the International Building Code (IBC) are. Specifically, the following sections are the most relevant to handrail and stair rail requirements. For example, there is a system (Ex. 1926. You can also reach out to us online or call at 888-637-7872 to talk to a knowledgeable associate. Guardrails need to have a minimum breaking strength of 200 lbs. OSHA recognized that guardrail systems, safety net systems and personal fall arrest systems could pose feasibility problems during roofing work; therefore, the rule allows other choices of fall protection methods. 1926. 29 (b) (1) The top edge height of top rails, or equivalent guardrail system members, are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the. system, except those on single-point and two-point adjustable suspension scaffolds. In addition to wearing hard hats each employee on a scaffold shall be provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, or guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the. in any direction per OSHA 1910. The roadway may be abutted by steep embankments or side slopes, or it. Please review the full code for further information. A safe and effective way to protect the perimeter of your excavation, our guardrails are easy to install to the wall of your shoring system quickly. Despite its high fatality rate, construction can be a safe occupation when workers are aware of the hazards, and their employer implements an effective Safety and Health Program. Particular industries require certain specifications on safety railing systems. This appendix serves as a. The employer must ensure: ( i) Each employee on a scaffold is protected from falling in accordance 29 CFR part 1926, subpart L; and. Rail - galvanized 155278 Pin with bail, zinc plated Material 16 gauge Steel Top rail height 42” Mid-rail height 21” Outer diameter 1. The roof guardrail system easily adapts to changes in roof elevations and sharp angles. 91 - $382. Further, OSHA standard 1910. Automotive. 28; 1910. POST: 1 5/8" Steel Tubing x 16ga. The GuardRail protective railing system comes in two styles: Single or Double Rail. 1-2007, Safety Requirements for Workplace Walking/Working Surfaces and Their Access; Workplace Floor, Wall and Roof Openings; Stairs and Guardrail Systems. When access to the entire roof is required, the safest, most comprehensive solution is a perimeter rooftop guardrail system or safety guardrail that surrounds and protects all roof edges. 3 Subject to section 14. 29 (b) (1) The top edge height of top rails, or equivalent guardrail system members, are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface. 28(b)(13)(iii)(A) requires protection from falls “by a guardrail system, safety net system, travel restraint system, or personal fall arrest system or designated area. OSHA promulgated existing Sec. OSHA 1926. (1) This section sets forth requirements for employers to provide fall protection systems. D. The guardrail system is used to prevent an employee from falling to a level or the ground below. Spatz: Thank you for your March 24, 2018, letter we received via email to the Occupational Safety and Health Administration (OSHA) Directorate of Construction regarding applicability of scaffold fall protection requirements. 501 (b)2ii states: “Each employee on a walking/working. 1926. Vertical mounted Permanent Mount bases are anchored to vertical surfaces and use our long leg rail to establish an OSHA-compliant guardrail system. The Guardian G-Rail system is a. Sets forth safety requirements for areas where danger exists of persons or objects falling through floor or wall openings,. 501(b)(13) Workers engaged in residential construction 6 feet or more above lower levels must be protected by conventional fall protection (i. Safety yellow SafePro roof guardrails are available in 6’, 8’, and 10’ sections. Home. SKU: 15170. The guardrails provided here are 1-1/4” thick. In general, fall protection is required when employees work on walking or working surfaces that are 6 feet or more above lower levels. TREADS must support ≥ 1,000 lb, minimum depth ≥ 9. Guardrails are a preferred means of protecting workers because the system does not rely on the worker to be trained to use, inspect, and wear a fall protection system. This would include situation number five, above. America's Safest Companies. Find out which FIXFAST USA guardrail system is best for you. Using safety railing and guardrail systems is one way to help prevent falls and their resulting injuries. To meet OSHA requirements in the construction industry, if workers are six feet or more above a lower level, there must be protection from falling by the use of. Factory Supply supplies, builds, designs and custom engineers OSHA and ANSI compliant rooftop guardrail systems for fall protection. Compatible with all Leading Edge Safety Railing. In particular, toeboards used for falling object protection are as follows: Toe Board Height Requirements: 29 (k) (1) (ii): “have a vertical minimum height of 3. The OSHA guidelines for guardrails are very specific, but they aren't difficult to follow. Spiral stairs must meet the. Interleaves with shingles. 29, except that personal fall protection systems required by this. 502. OSHA’s rules for fall protection in the construction industry are found at 29 CFR 1926, Subpart M. Sections 1926. Omega guardrails brackets allow the mounting of metal guard rails systems in a variety of ways. The United States Department of Labor's Occupational Safety and Health Administration (OSHA) has issued a directive rescinding the Interim Fall Protection Compliance Guidelines for Residential Construction (STD 03-00-001). 42 Guardrail systems shall be capable of withstanding, without failure, a force of at least ___ pounds applied within 2 inches of the top edge, in any outward or downward direction, at any point along. Safety Boot Guardrail System ® Safety Boot ® Tall Guardrail Brace Provides Guardrail Protection Up To 65 Inches P. Further, the non-penetrating design eliminates any holes in the roof and roof hatch. People assume they are protected by “guardrails”. Kee Guard Contractor safety railing is versatile, easy to assemble, and gives you an innovative approach to durable portable safety railing systems for roofs up to a 5 degree pitch. When midrails are used, they must be installed at a height approximately midway between the top edge of the guardrail system and the platform surface. OSHA roof guardrail requirements state that the top rails and the mid-rails of the guardrail system must bet at least one-quarter of an inch thick. Designed to be quickly installed, our guardrail can be used at perimeters, open. Solar panels should be lifted safely to the rooftops. to decrees falls using portable ladders, OSHA requires that ladder rungs are. TO: ALL AREA DIRECTORS Paragraph 1926. 2. 23 (a) (1) Used in emergency operations such as firefighting, rescue, and tactical law enforcement operations, or training for these operations; or. Mast Climbing Scaffold Engineering Investigations and Analyses. OSHA compliant instructions attached to each section. 761 (c) (2) (i) The nature of the hazards associated with connecting; and. Fall protection includes guardrail systems and personal fall arrest systems. The use of a fall protection system is not required for a repair pit, service pit, or assembly pit that is less than 10Paragraphs (b), (c) and (f) of § 1926. As for the safety railings and guardrails, you’ll find adjustable and nonadjustable. e. OSHA discussed the reasons for this belief when it published the final rule for the built-up roofing standard (45 FR 75619). Railings: 1-5/8 inch (41 mm) O. The maximum safety for Fall Protection . 29 (b) (1): The top edge height of top rails, or equivalent guardrail system members, are 42. 451–1926. Our portable guard railing is 42 inches tall. KeeGuard is one of the only 3rd-party tested fall protection guardrail systems available. This guide from the National Safety Council provides an overview of guardrail systems, their components, installation, inspection and maintenance. 1910. Warning line system: A barrier erected on a roof to warn employees that they are approaching an unprotected roof side or edge, and which designates an area in which roofing work may take place without the use of guardrail, body belt, or safety net systems to protect employees in the area. The employer is not required to provide any fall protection, provided the work is both infrequent and temporary; and”OSHA 1910 Occupational Safety and Health Standards > D Walking-Working Surfaces > 1910. ladders on a slippery surface must be. 28 Duty To Have Fall Protection and Falling Object Protection Existing §1910. OSHA guardrails and roof railings ensure OSHA Compliance using a passive fall protection system. Fall arrest system 4. 500(a)(2) or in 1926. See WAC 296-32-22555 (5) (c) for guarding ramps, runways, and inclined walkways that are four feet or more above the ground or lower level. In addition to wearing hard hats each employee on a scaffold shall be provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, or guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects. OSHA Instruction STD 3-10. •Guardrail systems •Safety net systems •Personal Fall Arrest Systems •Positioning systems •Travel Restraint systems •Ladder Safety systems. A personal fall-arrest system is a system used to arrest an employee in a fall from a working level. 501 (b)(1) through (b)(14), each employee on a walking/working surface 6 feet (1. Components of a Guardrail. OSHA's fall protection standard for construction, 29 CFR Part 1926 Subpart M (Fall Protection) ("Standard"), as well as its related Directive Number STD 3-01. 8 m) or more above lower levels shall be protected from falling by a guardrail system, safety net system, or personal fall arrest system. The AccuFit 360 flat roof free standing safety railing is a completely non-penetrating rooftop hand rail and guardrail system. CAL/OSHA COMPLIANCE: This guardrail system if installed in the state of California or Washington, requires a maximum spacing between uprights/stanchions of 8 feet on center (96 inches or 2. 501(b)(13), workers engaged in residential construction six (6) feet or more above lower levels must be protected by conventional fall protection (in other words, guardrail systems, safety net systems, or personal fall arrest systems) or other fall protection measures allowed elsewhere in 1926. The maximum deflection of the top rail when a load. The three basic rail systems are based on the 2006 International Building Code (IBC 1013, “Guards”), the American Association of State Highway and Transportation Offi cials “AASHTO LRFD (Load and Resistance Factor Design) Bridge Design Specifications,” and the Occupational Safety and Health Administration rail system (OSHA, CFR 29, Part. Guardrail systems with toeboards, Safety net systems, or Personal fall arrest systems. The agency has received numerous questions asking when handrails are required, and about the height requirements for handrails on stairs and stair rail systems. Under paragraph 1926. Fall protection is required for employees when working 10' or more above the next lower level. 8 meters) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Bracket Type. 1, Safety Requirements for Workplace Walking/Working Surfaces and Their Access; Workplace Floor, Wall and Roof Openings; Stairs and Guardrail Systems. 0 ˜ . 152 (f) (2) Leakage or spillage of flammable liquids shall be disposed of promptly and safely. 1910. Guardrail Systems—1926. Infrequent is defined as once a month or less, while. Minimize your labor hours, eliminate ongoing maintenance during your projects, and eliminate wasteful 2x4s. (a) General. and the toeboard. If guardrail systems, personal fall arrest systems. According to OSHA 29 CFR 1926. If you need a railing for your worksite, G-rail will get the job done!Roof Guardrail. 107 provide definitions for the pertinent terms. ( ii) Each employee using a rope descent system 4 feet (1. oriented recommendations for the design, . OSHA 1926. 28 (b) (1) (i) The top rail is smooth surfaced and is 42-inches nominal height and the railing system has the strength to withstand at least 200 pounds of applied top rail pressure. " Except as otherwise provided in paragraph (b) of this. 152 (f) (3) Category 1, 2, or 3 flammable liquids may be used only. 29 (k) includes standards for “protection from falling objects”. Positions for various roof pitches from 4/12 to 16/12. 500 (a) (2) or in § 1926. Standard Number: 1926. 451(g)(1)(i) through (vi), and are. OSHA's fall protection standard for construction, 29 CFR Part 1926 Subpart M (Fall Protection) ("Standard"), as well as its related Directive Number STD 3-01. With Garlock Safety Systems ®, you have the most trusted name in passive fall protection working for you, and you know it. hot rolled pickled electric weld tubing, free of sharp edges and snag points. Modular systems are versatile and can be installed in such a way that the. Unistrut Service Company offers modular rooftop guardrail systems that eliminate fall hazards and meet or exceed OSHA requirements. 29 repeats itself a lot and it can be a little confusing to sort through. However, OSHA 1910. Top rail to walking-working surface should be around 42 inches – allows flexibility for +/-3 inches. KeeGuard Rooftop Guardrail is the most common. x 4 in. 1926. You can also reach out to us online or call at 888-637-7872 to talk to a knowledgeable associate. The hazards addressed in this eTool * have been. Railings: 1-5/8 inch (41 mm) O. Except as provided in § 1926. 501 (b) (10) – except as otherwise provided in paragraph (b. 502 (see Appendix G to this subpart). With bracket and post. 2 Guardrail Systems. Our KATTGUARD roof guardrail systems provide continuous fall protection to keep safety a priority while working on a roof. Guardrail is required for any platform 4. 00 – $ 315. (2) Leading edges. hot rolled pickled electric weld tubing, free of sharp edges and snag points. Double guard rail columns are 43″ high. 502 of this subpart. So, workers are using 30 inch stilts, the guardrail needs to be 72 inches tall (42 inches plus 30 inches). Born in the. In some cases and places, however, that is not possible. 29 CFR 1926. Falling object protection. Fall protection systems criteria and practices. American National Standards Institute (ANSI) ANSI/ASSE A1264. 6 m) above a lower level shall be protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems. 26. Guardrail systems must be capable of withstanding at least 200 pounds of force applied within 2 inches of the top edge, in any direction and at any point along the edge, and without causing the top edge of the guardrail to deflect downward to a height less than 39 inches above the walking/working level. 501 Duty to have fall protection. The ballasted guardrail system uses weighted bases that can be configured to your roof for permanent edge protection. Guardrail Systems (Requirements) The top edge height of top rails, or equivalent guardrail system members, is 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface except: guardrails on scaffolds manufactured after January 1, 2000, are 38 to 45 inches high and guardrails on scaffolds in service before January 1. Browse Construction Railing Systems. In combination with other safety hazards, safety prevention could save the lives of 468 workers per year. Ground-Based Guardrail Systems. Employees that are more than 10 feet off the ground need to be protected by using fall arrest systems or guardrails, except for employees that are on single-point and two-point adjustable suspension scaffolds. 501(b) for particular types of work. Guardrail system can also be provided around the excavated area as a barrier. Paragraph (g)(4)(I) provides that guardrail systems be installed along all open. 72. Where a mason performs overhand bricklaying and related work 6 feet above lower levels, the requirements for fall protection systems can be satisfied by the use of guardrail systems, safety net systems, personal fall arrest systems, or by creating a controlled access zone in which the mason works. Fall protection in general—and the use of railings and guardrail systems in particular—is covered under OSHA’s walking and working surfaces rule, 1910 Subpart D, which was updated in 2017. You’re completely OSHA compliant for inspection at a moments notice. 25 (b) (2) Vertical clearance above any stair tread to any overhead obstruction is at least 6 feet, 8 inches (203 cm), as measured from the leading edge of the tread. A safety handrail provides stability with a handhold on a platform, walkway, stairway or. Guardrail System. 1B, August 14, 1972. , guardrail systems, safety net systems, orPersonal fall arrest or restraint systems must be used when there is a gap in the guardrail system. Often rented by the General Contractor on large jobs, guardrails can also be rented by roofers, framers, concrete repair, HVAC, and steel erectors. Optional body belt B. This safety guardrail is easy to install and all you need is a hex key for. Need shorter railings? You can cut them shorter too. Some of the relevant provisions state: (vii) Each toprail or equivalent member of a guardrail system shall be capable of withstanding, without failure, a force applied in any downward or horizontal. Rail - galvanized 406930G 8. OSHA’s rules for fall protection in the construction industry are found at 29 CFR 1926, Subpart M. 761 (c) (1) (ii) The proper procedures and equipment to perform multiple lifts required by § 1926. 8 m) or more above lower levels shall be protected from falling by a guardrail system, safety net system, or personal fall arrest system. Raleigh, NC 27603 Tel: 1-800-582-0533; 1-919-656-1925 E-mail: [email protected] Cal 3209 Designed for compliance under both federal OSHA regulations and the more stringent Cal-OSHA guidelines, the Accu-Fit Cal 1620 rail system is a complete fall-protection solution. Mon - Fri: 7:00 - 4:30 EST. Please review the full code for further. e. 29 & 1926. 501(b)(12), and 1926. NCHRP Roadside Hardware Replacement Analysis: User Guide. 6 feet (1. Guardrail systems. 451(a)(5) is acceptable provided it meets the following guidelines: Except as provided in § 1926. 501? Answer Title 29 CFR Part 1926 Subpart M - Fall Protection, §1926. 28 (b) (13) (ii) When work is performed at least 6 feet (1. According to OSHA 1917. Lab testing has verified that hand tightening is sufficient to ensure that cross-members will not slip down the vertical tube when contacted with a 200-lb force, as. From temporary, free-standing safety railing systems to permanent installations, guardrail solutions can keep your employees safe and. 451(g)(1) • Guardrail height—The height of the toprail forThe employer must ensure: 1910. Fully Tested & Exceeds Current Safety Requirements. Ideal for contractors during construction, this guardrail eliminates the need for tie-off points and expensive safety equipment. 451(g). This rooftop safety guardrail solution protects people from hazards. (1) This section requires employers to provide protection for each employee exposed to fall and falling object hazards. ±3 in. Safety Railing and Guardrail Systems. construction and evaluation of guardrail systems which come under the jurisdiction of OSHA. Rail section made from 1-5/8 inch steel tubing. (3) Holes. 501(b)(1) by raising the top rails on the pictured catch platform to a height 39-45 inches above the walking/working surface of. Kee Guard is the industry leading modular, free-standing safety railing system that is not fixed directly to the roof membrane. Height: 42 inches (1067 mm), and 48 inches (1219 mm). Rail - safety yellow 402337S 5. Mounting Bases: Available as single and double post mounts. The end treatment tests are then conducted by having a vehicle strike the rail dead-on and also at an angle. Under 29 CFR 1926. 501(b). Connecting device (lanyard with shock absorber/retractable lifeline, snap hooks) C. Full-service FRP Solutions. EHS Intelligence Environment Health Safety Leadership Standards Construction PPE Safety Technology Training & Engagement Emergency Management COVID-19 Crisis Industrial Hygiene. Workers should never be allowed to climb ladders while carrying solar panels. Where workers on a construction site are exposed to vertical drops of 6 feet or more, OSHA requires that employers provide fall protection in one of three ways before work begins: Placing guardrails around the hazard. Applicability of scaffold fall protection to guardrails near ladder access areas on scaffolds; toeboards across ladder access areas. Fall Protection on scaffolds OSHA scaffolding standards are at volume 29 of the Code of Federal Regulations (CFR) sections 1926. The posts to be 1 1/2-inch outside diameter or larger, the spacing not to exceed 8 feet. 62” EDGE Fall Protection’s Cal OSHA Guardrail is a system specifically designed for compliance with California OSHA Title 9, 1620 and 3209 regulations. The top edge height may exceed 45 inches (114 cm), provided the guardrail system meets all other criteria of paragraph (b) of this section (see Figure D–11 of this section). The employer could potentially have complied with 1926. Anti-jerk cord D. Frontline presents it's patent pending guardrail system, the lightest and most innovative fall prevention guardrail system in the market! The guardrail system is completely non-penetrating, manufactured out of high strength ASTM rated steel and painted with safety green or safety yellow electrostatic paint for long lasting durability and added visibility at. ”. an unprotected side or edge which is 6 feet or more above a lower level shall be protected from falling by the use of guardrail systems, safety net. (vi)] of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph [1926. 28(b)(9)).